Initial Inspection and Diagnostic Overview
The dome light does not illuminate.1. The clock is stopped also.
- Check dedicated fuse No. 12
2. The dome light does not illuminate when with the dome light switch at the "DOOR" position, any door is opened.
- Check the bulb.
- Check the dome light switch.
3. The dome light does not illuminate when, with the dome light switch at the "DOOR" position, a certain door or doors is/are opened.
- Check the door switch [the door switches) for the door(s) that does not activate the dome light when opened].