Test Values For Timing
Test Values For Timing
Timing of inlet valve at 2 mm valve lift and new timing chain
Opens after TDC 30 ± 2 degrees CKA
closes after BDC 30.7 ± 2 degrees CKA
Timing of exhaust valve at 2 mm valve lift and new timing chain
Opens before BDC 7 ± 2 degrees CKA
closes before TDC 7 degrees CKA