Condenser Fan Motor: Testing and Inspection
CONDENSER FAN INSPECTION1. Disconnect the condenser fan connector.
2. Connect battery positive voltage to terminal A and ground to terminal B of the condenser fan and verify its operation.
If not as specified, replace the condenser fan.