Engine - Hard To Start/Excessive Cranking Time
Bulletin No. 003/99Issued 03/04/99
Revised
Section
F (01)
Applicable Model/s
1999 Miata
Subject
ENGINE HARD TO START/EXCESSIVE
CRANKING TIME
APPLICABLE MODEL(S)/VINS
All 1999 Miatas with VINs lower than JM1NB35**X0122622.
DESCRIPTION
Hard starting or excessive cranking time may occur on some vehicles. This may be caused by foreign substances entering the fuel system during vehicle production. The substances may accumulate at the fuel pressure regulator valve causing it to stick open. Production and handling procedures have been changed to prevent this condition. Customers complaining of this concern should have their vehicle repaired using the following procedure.
REPAIR PROCEDURE
1. Inspect the fuel hold pressure (five minutes after turning the key to the "OFF" position). For detailed procedure, refer to the Workshop Manual (section 01).
If the fuel hold pressure is less than 250 kPa (2.55 kgf/sq.cm 36.3 psi), replace the pressure regulator with a modified part.
If the fuel hold pressure is more than 250 kPa (2.55 kgf/sq.cm, 36.3 psi}, there is no problem in the fuel pressure regulator. Refer to the troubleshooting guide in the Workshop Manual.
2. Verify repair.
PART(S) INFORMATION
Part Number Description Qty. Notes
BP4W 13 280 Pressure Regulator 1 --
WARRANTY INFORMATION
Note
This information applies to verified customer complaints on vehicles covered under normal warranty. Refer to the SRT microfiche for warranty term information.
Warranty Type A
Symptom Code 02
Damage Code 93
Part Number Main Cause BP4W 13 280
Quantity 1
Operation Number / Labor Hours F0306XRX / 0.7