Shift Solenoid C
Shift Solenoid C:
SHIFT SOLENOID C
- If there is an open or short circuit in the shift solenoid C or harness, diagnostic trouble code PO76O is displayed by the on-board diagnostic system and O/D OFF mode is canceled.
- If a malfunction occurs in the shift solenoid C, the solenoid valve turns OFF and torque converter clutch operation is canceled.