Shift Solenoid A
Shift Solenoid A:
SHIFT SOLENOID A
- If there is an open or short circuit in the shift solenoid A or harness, diagnostic trouble code PO75O is displayed by the on-board diagnostic system and O/D OFF mode is canceled.
- If a malfunction occurs in the shift solenoid A, the solenoid valve turns OFF and torque converter clutch operation is canceled.