Variable Induction System: Testing and Inspection
View: Tachometer Connections:
1. Start engine and run at idle.
2. Connect tachometer to the data link connector IG-terminal as shown.
View: Shutter Valve Operating Chart:
View: Shutter Valve Actuators:
3. Open throttle and verify that rod is pulled into shutter valve actuators 1 and 2 at engine speed specified on chart.
NOTE: Shutter valve actuator operation cannot be checked unless a load condition exists while engine speed is within 1900 - 2600 rpm as shown on chart.