Condenser Fan Control System (A/C Equipped )
PURPOSETo improve A/C operating efficiency.
View: Condenser Fan Control System (A/C Equipped):
CONSTRUCTION
There are three relays (High No. 1, No. 2 and low) which control the condenser fan operation along with the powertrain control module engine (PCME) and various PCME inputs.
Fig.3 Condenser Fan Control System Operating Conditions:
OPERATION
The condenser fan is operated at three speeds: low, medium and high. These controls operate under the conditions shown in Fig.3