Motor Inspection
1. Ensure ignition switch is in Off position, then disconnect hydraulic unit two pin connector.2. Measure resistance between connector terminals; resistance should be 1 ohm.
3. Apply battery voltage to connector, ensure motor is operating.
4. If not as specified, replace hydraulic unit.