Power Liftgate (PLG) Front Switch Inspection
POWER LIFTGATE (PLG) FRONT SWITCH INSPECTION
1. Verify that the continuity between the PLG front switch terminals is as indicated in the table.
- If not as indicated in the table, replace the PLG front switch.
2. Apply battery voltage to PLG front switch terminal A, and connect terminal B to ground.
3. Verify that the LED illuminates.
- If there is any malfunction, replace the PLG front switch.