Air Cleaner Intake Pipe Removal/Installation
AIR CLEANER INTAKE PIPE REMOVAL/INSTALLATION - 2.5L
1. Remove the battery tray. See Service and Repair.
2. Remove the bolt and the intake pipe.
- To install, tighten to 8 Nm {0.8 kgf-m, 71 in-lbf}.
3. To install, reverse the removal procedure.
NOTE:Make sure that the front sponge seal of the intake pipe is seated on the shroud panel.