SST, SS2, SS3, SS4 and TCC In Bench Mode
SST, SS2, SS3, SS4 and TCC in BENCH MODE:The BENCH MODE allows the technician to perform electrical circuit checks on the following components:
^ SS1 - Activates SS1 OFF or ON.
^ SS2 - Activates SS2 OFF or ON.
^ SS3 - Activates SS3 OFF or ON.
^ SS4 - Activates SS4 OFF or ON.
^ TCC - Activates TCC OFF or ON.
OSC "SST, SS2, SS3, SS4, TCC" BENCH MODE Operates ONLY when:
^ VSS and digital TR sensor are operational
^ No VSS and digital TR sensor DTCs.
^ Transmission range selector lever in P.
^ Key ON.
^ Key OFF. OSC Command Values
^ [OFF] - turns solenoid OFF.
^ [ON] - turns solenoid ON.
^ [XXX] - cancels OSC value sent.
^ [SEND] - sends the values to PCM.
BENCH MODE Procedure for SST, SS2, SS3, SS4, and TCC
Follow operating instructions from the WDS or equivalent tester menu screen:
^ Select "Output State Control."
^ Select"Trans- Bench Mode."
^ Select "PIDs" to be monitored.
^ Monitor all selected PIDs during test.
^ Select "parameters - SS1, SS2, SS3, SS4, or TCC."
^ Select "ON" to turn solenoid ON.
^ Press "SEND" to send command ON.
^ Select "OFF" to turn solenoid OFF.
^ Press "SEND" to send command OFF.
^ Select "XXX" to cancel at any time.
^ Press "SEND."