Curiosii for ever!: Car repair manuals for everyone.

Canister Purge Control Valve: Service and Repair

FUEL CANISTER PURGE VALVE REMOVAL / INSTALLATION

1. Disconnect vacuum line.
2. Disconnect electrical connector.
3. Disconnect the evaporative emissions service port-to-fuel vapor management valve tube.




4. Disconnect the throttle body spacer-to-fuel vapor management valve tube.
5. Remove the two bolts.
6. Remove the valve.

Tightening torque
8 - 9 N.m { 82 - 92 kgf.cm, 71 - 79 in.lbf }

7. Install in reverse order of removal.
8. Leak test the Evaporative Emissions System.