Positive Crankcase Ventilation Valve: Service and Repair
POSITIVE CRANKCASE VENTILATION (PCV) VALVERemoval and Installation
1. Disconnect the PCV hose.
2. Disconnect the PCV valve electrical connector.
3. CAUTION: A new PCV valve must be installed if removed from the cam cover. Damage will occur to the locking mechanism or the PCV valve.
Remove the PCV valve.
- Twist the PCV valve counterclockwise to remove the PCV valve from the valve cover.
4. To install, reverse the removal procedure.