Blower Motor Resistor: Service and Repair
REMOVE- Disconnect the battery negative lead and remove cowl panel.
Blower Resistor:
- Remove the two screws (2) securing the resistor.
- Release the grommet (3) from the housing.
- Remove the four screws (4) from the front dash closing panel.
- Trace the resistor electrical wiring to the multiplug and disconnect.
- Remove the resistor (6) complete with wiring and multiplug.
REFIT
- Reverse the removal instructions.