Right Hand Drive
The Powertrain Control Module (PCM) operates the idle air control motor through 4 circuits - K39, K40, K59 and K60. Each circuit connects to separate cavities in the PCM connector.- Circuit K39 connects to cavity 39 of the PCM
- Circuit K40 connects to cavity 40 of the PCM
- Circuit K59 connects to cavity 59 of the PCM
- Circuit K60 connects to cavity 60 of the PCM