Curiosii for ever!: Car repair manuals for everyone.

Valve Body, A/T

Shift Solenoid Valve A
Between terminal 2 and ground Approx. 20 - 30 Ohms

Shift Solenoid Valve B
Between terminal 1 and ground Approx. 20 - 30 Ohms

Overrun Clutch Solenoid Valve
Between terminal 3 and ground Approx. 20 - 30 Ohms

Line Pressure Solenoid Valve
Between terminal 4 and ground Approx. 2.5 - 5.0 Ohms

Torque Converter Clutch Solenoid Valve
Between terminal 5 and ground Approx. 10 - 16 Ohms