Condenser Pipe Assembly
CONDENSER
CONDENSER PIPE ASSEMBLY : Removal and Installation
REMOVAL
1. Use a refrigerant collecting equipment (for HFC-134a) to discharge the refrigerant.
2. Remove air cleaner case (bank 2). Refer to Exploded View.
3. Remove air duct (inlet). Refer to Exploded View.
4. Remove front grille. Refer to Exploded View.
5. Remove mounting bolts (A) from condenser pipe assembly (1).
6. Disconnect one-touch joint between high-pressure flexible hose
(1) and condenser pipe assembly (3) with disconnector (A)
(SST: 9253089912).
CAUTION:
Cap or wrap the joint of the A/C piping with suitable material such as vinyl tape to avoid the entry of air.
7. Disconnect one-touch joint between high-pressure pipe 1 (2) and condenser pipe assembly with disconnector (A) (SST:
9253089908).
CAUTION:
Cap or wrap the joint of the A/C piping with suitable material such as vinyl tape to avoid the entry of air.
8. Remove condenser pipe assembly.
CAUTION:
Cap or wrap the joint of the A/C piping and condenser with suitable material such as vinyl tape to avoid the entry of air.
INSTALLATION
Installation is basically the reverse order of removal.
CAUTION:
- Replace O-rings with new ones. Then apply compressor oil to them when installing.
- Female-side piping connection is thin and easy to deform. Slowly insert the male-side piping straight in axial direction.
- Insert piping securely until a click is heard.
- After piping connection is completed, pull male-side piping by hand to make sure that connection does not come loose.
- Check for leakages when recharging refrigerant.