Drive Pulley: Service and Repair
REMOVAL
1. Loosen the coolant pump pulley bolts.
2. Loosen the generator support nut.
3. Loosen the generator lock bolt, and remove the belt.
4. Remove the coolant pump pulley bolts, then the pulley.
INSTALLATION
1. Install the coolant pump pulley to the coolant pump pulley bracket and tighten the bolts to 8-10 Nm (80-100 kg. cm, 6-7 ft. lbs.).
2. After installing the belt, adjust the belt tension.
3. After tensioning belt tighten mountings as follows:
Generator support nut A: 20-25 Nm (200-250 kg.cm, 14-18 ft. lbs.).
Generator lock bolt B: 15-22 Nm (150-220 kg.cm, 11-16 ft. lbs.).
Generator brace mounting bolt: 20-28 Nm (200-280 kg.cm, 14-20 ft. lbs.).