Curiosii for ever!: Car repair manuals for everyone.

Alternator

REMOVAL
1. Loosen the coolant pump pulley bolts.






2. Loosen the generator support nut.
3. Loosen the generator lock bolt, and remove the belt.

INSTALLATION
1. Install the belt, then adjust the belt tension.
3. After tensioning belt tighten mountings as follows:
Generator support nut A: 20-25 Nm (200-250 kg. cm, 14-18 ft. lbs.).
Generator lock bolt B: 15-22 Nm (150-220 kg. cm, 11-16 ft. lbs.).
Generator brace mounting bolt: 20-28 Nm (200-280 kg. cm, 14-20 ft. lbs.).