Curiosii for ever!: Car repair manuals for everyone.

Disposal

Fig. 79 Relieving Nitrogen Gas From Accumulator For Disposal:





The accumulator contains high pressure nitrogen gas. Do not puncture, expose to flame or attempt to disassemble the accumulator or it may explode.
1. Secure accumulator in a vise with relief plug pointing straight up, Fig. 79.
2. Slowly turn plug three and one half turns and wait three minutes for all pressure to escape.
3. Remove plug completely and dispose of accumulator unit.