Accumulator HVAC: Service and Repair
REMOVAL1. Recover the refrigerant.
2. Disconnect the A/C cycling switch connector.
3. Remove the A/C cycling switch.
4. Disconnect the A/C manifold and tube from the suction accumulator/drier; refer to the Spring Lock Coupling Disconnect and Connect general procedure. Spring Lock Coupling Connect and Disconnect Procedure
5. Disconnect the suction accumulator/drier from the A/C evaporator core.
CAUTION: To prevent damage to the fitting and the tube, use a backup wrench when removing the suction accumulator/drier.
6. Remove the clamp screw and remove the suction accumulator/drier.
INSTALLATION
1. Follow the removal procedure in reverse order.
^ Lubricate the A/C cycling switch O-ring seal with Motorcraft YN-12c refrigerant oil or equivalent meeting Ford specification WSH-M1C231-B.
CAUTION: To prevent damage to the fitting and the tube, use a backup wrench when installing the suction accumulator/drier.