Curiosii for ever!: Car repair manuals for everyone.

Intermittent Wiper Relay Voltage Check

With column switch connected, ignition switch in ACC position, wiper switch in INT position, check voltage between terminal three and ground. Voltage should alternate from zero to system volts.