Integrated Control Unit (ICU) - Assembly






ASSEMBLY

1. Install the CAB on the HCU lining up the solenoids with the valves.









2. Install the four bolts (1) mounting the CAB (2) to the HCU (3). Tighten the CAB mounting bolts to 2 Nm (17 in. lbs.).










3. Plug the pump/motor wiring harness (2) into the CAB (1).

4. Install the ICU in the vehicle. Integrated Control Unit (ICU) - Installation