UART
The UART serial data communication relies on a
5 volt digital signal for the exchange of data between different control modules and to provide scan tool diagnostic data. When the
ignition switch is in the RUN position and the UART line is at rest, i.e. no communication taking place, the voltage remains HIGH at approximately
5 volts. When data is transmitted the voltage is cycled to ground, approximately
0 volts.