Curiosii for ever!: Car repair manuals for everyone.

Blower Motor Resistor Replacement (RPO YG6)

REMOVAL PROCEDURE




1. Remove the air cleaner.
2. Remove the windshield washers and the coolant reservoir for access.
3. Disconnect the electrical connectors.
4. Remove the screws from the blower motor resistor.
It is not necessary to remove the heater case.
5. Remove the blower motor resistor.

INSTALLATION PROCEDURE




1. Install the blower motor resistor.

NOTE: Refer to Fastener Notice in Service Precautions.

2. Install the screws to the blower motor resistor.

Tighten
Tighten the screws to the blower motor resistor to 2 N.m (18 lb in).

3. Connect the electrical connectors.
4. Install the windshield washers and the coolant reservoir. Coolant Recovery Reservoir Replacement in Engine Coolant.
5. Ensure that the circuit operates properly.
6. Install the air cleaner.

For a description of the RPO Code(s) shown in this article/images refer to the RPO Code List found at Vehicle/Application ID RPO Codes