Wiper Motor Module Replacement
REMOVAL PROCEDURECAUTION: Refer to Battery Disconnect Caution in Cautions and Notices.
1. Disconnect the negative battery cable.
2. Disconnect the wiper motor electrical connector.
3. Remove the screws.
4. Remove the cover.
5. Lift up the terminal. Remove the circuit board and terminal assembly.
INSTALLATION PROCEDURE
1. Install the circuit board and terminal assembly
2. Install the cover.
3. Install the screws.
Tighten
Tighten the screws to 2.6 N.m (23 lb in).
4. Connect the wiper motor electrical connector.
CAUTION: Refer to Battery Disconnect Caution in Cautions and Notices.
5. Connect the negative battery cable.