Resonator: Service and Repair
AIR CLEANER OUTLET RESONATOR REPLACEMENT
REMOVAL PROCEDURE
1. Reposition the positive crankcase ventilation (PCV) clean air tube clamp.
2. Remove the PCV clean air tube from the outlet duct.
3. Loosen the outlet air duct clamps from the air cleaner cover and the throttle body.
4. Remove the air outlet duct from the air cleaner cover and the throttle body.
INSTALLATION PROCEDURE
1. Install the air outlet duct to the air cleaner cover and the throttle body.
NOTE: Refer to Fastener Notice in Service Precautions.
2. Tighten the outlet air duct clamps to the air cleaner cover and the throttle body.
Tighten the clamps to 2 N.m (18 lb in).
3. Install the PCV clean air tube to the outlet duct.
4. Position the PCV clean air tube clamp.