Alternator Pulley / Clutch: Service and Repair
REMOVAL PROCEDURECAUTION: Refer to Battery Disconnect Caution in Cautions and Notices.
1. Disconnect the negative battery cable.
2. Remove the accessory drive belt.
3. Install a T-50(R) torx bit into the generator shaft.
4. Remove the generator shaft nut and washer.
5. Remove the generator pulley.
INSTALLATION PROCEDURE
NOTE: Refer to Fastener Notice in Cautions and Notices.
1. Install the generator pulley, washer and shaft nut.
Tighten
Tighten the generator shaft nut to 75 N.m (55 lb ft).
2. Install the accessory drive belt (5).