O-Rings
IMPORTANT: Install the new GM approved service replacement air conditioning O-rings to the following disassembled components (except when the new O-rings are provided with the new components):^ A joint
^ A fitting
Even though an O-ring may look the same, ensure that you use only the recommended service replacement O-rings. Excessive leakage of refrigerant may occur.
Always lubricate the O-ring using 525 viscosity refrigerant mineral oil. Slip the O-ring onto the flange tube in order to ensure the following conditions:
^ Proper locating
^ Proper sealing
Do not lubricate the O-rings using PAG refrigerant oil in order to prevent the following conditions:
^ Swelling
^ A reduction in sealing effectiveness
Prior to installation, verify that the O-rings and the fittings are not in the following condition:
^ Nicked
^ Deformed
Replace the O-rings or fittings that are in the following condition:
^ Nicked
^ Deformed
Failure to use the following service requirements may result in excessive refrigerant-leakage:
^ The proper service replacement parts
^ The proper service replacement procedures