Curiosii for ever!: Car repair manuals for everyone.

P0341












Circuit Description

The Camshaft Position Sensor (CMP) correlates the crankshaft to camshaft position so that the Powertrain Control Module (PCM) can determine which cylinder is ready to be fueled by the injector. The CMP sensor also determines which cylinder is misfiring when a misfire is present. If the PCM receives an intermittent signal from the CMP, then the CMP Resync Counter will increment. When the PCM cannot use the information from the CMP sensor, a DTC is set and the PCM will fuel the engine by using the Alternating Synchronous Double Fire (ASDF) method.

Conditions for Running the DTC

The engine is running.

Conditions for Setting the DTC

The PCM sees more than 15 CMP sensor resyncs in 256 seconds (4 mn., 16 sec.).

Action Taken When the DTC Sets

^ The Malfunction Indicator Lamp (MIL) will illuminate after two consecutive ignition cycles in which the diagnostic runs with the fault active.

^ The PCM records the operating conditions at the time when the diagnostic fails. This information stores in the Freeze Frame and Failure Records buffers.

^ A history DTC stores.

^ The coolant fan turns ON.

Conditions for Clearing the MIL/DTC

^ The MIL will turn OFF after three consecutive ignition cycles in which the diagnostic runs without a fault.

^ A history DTC will clear after 40 consecutive warm up cycles without a fault

^ The MIL/DTCs can be cleared by using the scan tool.

Diagnostic Aids

^ An Intermittent problem may be caused by the following conditions:

- Poor electrical connection

- Rubbed through wire insulation

- Broken wire inside the insulation

^ Check any suspected circuitry for the following conditions:

- Backed out terminals

- Improper mating

- Broken locks

- Improperly formed

- Damaged terminals

- Poor terminal to wiring connections

- Physical damage to the wiring harness. If the PCM sees less than 15 resyncs in 256 seconds, the counter is reset to 0. Anytime a poor electrical connection is present, the CMP Reference Activity counter will stop incrementing and the CMP Resync Counter will increment.

Test Description

The number(s) below refer(s) to the step number(s) on the Diagnostic Table.

1. The Powertrain OBD System Check prompts you to complete some of the basic checks and to store the freeze frame and failure records data on the scan tool if applicable. This creates an electronic copy of the data captured when the malfunction occurred. The scan tool stores this data for later reference.

3. This step determines if the DTC P0341 is the result of a hard malfunction or an intermittent condition.

4. The counter should stop incrementing with the sensor electrical connector disconnected and set a DTC P0342. If the counter stills increments, this indicates that the PCM is malfunctioning.

5. By moving the CMP sensor electrical connector, the connections at the sensor are being checked. Make sure that the electrical connector remains securely fastened.

6. A poor electrical connection in any of the circuits at the CMP sensor will cause the CMP Resync Counter to increment. Anytime a poor electrical connection is present, the CMP Reference Activity counter will stop incrementing and the CMP Resync Counter will increment.

7. Reprogram the replacement PCM and perform the crankshaft position system variation procedure. Refer to the latest Techline procedures for PCM reprogramming and the CKP System Variation Learn Procedure for the crankshaft position system variation learn procedure.