Thermostat Bypass Hose: Service and Repair
Coolant Bypass Hose Replacement (LC3)
Removal Procedure
1. Drain the cooling system. Refer to Draining and Filling Cooling System (Static Fill) Draining and Filling Cooling System (GE 47719) .
2. Remove the water outlet housing.
3. Compress the clamp, and remove the bypass hose from the water outlet housing.
Installation Procedure
1. Compress the clamp and install the bypass hose to the water outlet housing.
2. Install the water outlet housing.
3. Fill the cooling system. Refer to Draining and Filling Cooling System (Static Fill) Draining and Filling Cooling System (GE 47719) .
4. Check the cooling system for leaks.