SERVICE PORTS REPLACEMENT

TOOLS REQUIRED
J 39400-A Halogen Leak Detector

REMOVAL PROCEDURE




1. Recover the refrigerant.
2. Remove the service fitting from the line.

INSTALLATION PROCEDURE
1. Lubricate the O-ring using 525 refrigerant oil.




2. Install the service fitting to the line.

NOTE: Refer to Fastener Notice in Service Precautions.

Tighten
Tighten the fitting to 12 N.m (9 lb ft).

3. Evacuate and recharge the A/C system.
4. Leak test the component fittings using the J 39400-A.