2-3 Shift Solenoid Valve Replacement
2-3 SHIFT SOLENOID VALVE REPLACEMENT
Removal Procedure
1. Remove the case side cover. Control Valve Body Cover Replacement
2. Disconnect the 2-3 shift solenoid electrical connector.
3. Remove the 2-3 shift solenoid (315B).
Installation Procedure
1. Install the 2-3 shift solenoid (315B).
2. Connect the 2-3 shift solenoid electrical connector.
3. Install the case side cover. Control Valve Body Cover Replacement
Important: It is recommended that transmission adaptive pressure (TAP) information be reset. Resetting the TAP values using a scan tool will erase all learned values in all cells. As a result, The ECM, PCM or TCM will need to relearn TAP values. Transmission performance may be affected as new TAP values are learned.
4. Reset the TAP values. Adapt Function