Hydraulic Assembly: Description and Operation
The pressure switch monitors primary brake system pressure. The normally closed switch opens when the brakes are applied and pressure exceeds
700 kPa (101 psi). If the brakes are manually applied during traction control mode, the BPMV pressure switch input, along with the brake switch input, signal the
EBTCM to disable traction control and allow manual braking.