Transmission Pressure Test Port: Service and Repair
REMOVE OR DISCONNECT
1. Line pressure pipe plug.
2. Install pressure gauge. Refer to TRANSMISSION TRANSAXLE DIAGNOSIS for line pressure test Procedure.
INSTALL OR CONNECT
NOTICE: Always use the correct fastener in the proper location. When you replace a fastener, use ONLY the exact part number for that application. The manufacturer will call out those fasteners that require a replacement after removal. The manufacturer will also call out the fasteners that require thread lockers or thread sealant. UNLESS OTHERWISE SPECIFIED, do not use supplemental coatings (paints, greases, or other corrosion inhibitors) on threaded fasteners or fastener joint interfaces. Generally, such coatings adversely affect the fastener torque and the joint clamping force, and may damage the fastener. When you install fasteners, use the correct tightening sequence and specifications. Following these instructions can help you avoid damage to parts and systems.
1. Remove pressure gauge.
2. Line pressure pipe plug.
- Tighten pipe plug to 11 Nm (97 inch lbs.).