Canister Purge Control Valve: Service and Repair
Purge Valve Locations:
1. Remove the right side air mass meter along with the connecting pipe and upper section of the air cleaner.
2. Mark the purge valves.
3. Remove the electrical connectors.
4. Disconnect the fuel hoses. Catch escaping fuel in a suitable container.
5. Remove the purge valves.
6. Reinstall valves in reverse order.