Blower Motor: Service and Repair
1. Remove cowl ventilation grille.
2. Remove rear hood seal from channel and the 12 screws securing air intake cover, then pull back cover.
3. Mark and disconnect hoses from vacuum servos.
4. Remove relay and bracket and the temperature sensor.
5. Release clamp securing blower motor cover, remove protective grille and slide cover to one side.
6. Remove blower motor assembly.