Measuring Block Values, Reading
^ after selecting program 02 for transmission electronics, read display
^ press keys 0 and 8 (this selects program 08 for reading measuring value block)
^ read display
^ press Q key to acknowledge input
^ read display
Note
The measuring block values can only be read with the tester program card 12 installed.
If program 08 cannot be accessed, have Service Manager verify that program card /2 is installed in VAG 1551.
^ press keys 0 and 1 (this selects group number 01 and displays values corresponding to group 01 in following chart)
^ press Q key to acknowledge input
^ read display
^ repeat group number entry for remaining groups (02 through 05) and press print key after each new display appears to print a record of diagnosis
^ see specified values on following pages
^ if specified values appear on all channels press --> key; the problem has not been found using this test sequence
^ if specified values are not observed, conduct return to basic setting (see Repair Manual microfiche, Group D3, section 80-1) and follow instructions in chart for further testing
This concludes measuring value block testing.