Accumulator HVAC: Service and Repair
Accumulator:
CAUTION:
Be sure A/C refrigerant system is completely discharged before removing components.
- Remove waterbox cover.
- Loosen tensioning strap.
- Remove refrigerant lines.
- Installation is reverse order.
- Do not reuse O-ring gaskets.
- Torque fittings: 42Nm (32.0 ft lb).
- Recharge refrigerant.